Product Categories
- Electric Motor (42)
- Marine Electric Motor (40)
- Industrial Motor (2)
- Hydraulic Motor (77)
- Control System (25)
Power: 0.12-600kW
Voltage:380V/440V
Frequency:50Hz/60Hz
Protection Class: IP44-56
Insulation Class: B/F/H
Keywords: Y-H Series Marine Three-phrase Asynchronous Motor, Three-phrase Motor, Asynchronous Motor, Y-H Series Motor
Y-H Series are totally-enclosed, fan-cooled three-phase marine motors of the squirrel-cage type. They are a design variation of the brand-new Y series developed recently and noted for their high efficiency and starting torque. The electric motors are applied for driving various machines on ships such as marine pumps, marine winch, marine capstan, marine cranes, marine generators, marine windlass, marine separators and other marine auxiliaries.
Vibration
The effective values of vibration intensity bound, measured at no-load conditions, do not exceed those given in the following table.
Frame Size | 80~132 | 160~225 | 250~355 |
Vibration Intensity Bound(mm/s) | 1.8 | 2.8 | 3.5 |
Installation Arrangements
B3——Horizontal, foot-mounted
B5——Horizontal, flange-mounted
B35——horizontal, foot and flange mounted
V1——Vertical, flange mounted
Frame Size | Mounted Arrangements(IM) |
80~225 | B3, B5, B35, V1 |
250~350 | B3, B35, V1 |
Power: 0.12-600kW
Voltage:380V/440V
Frequency:50Hz/60Hz
Protection Class: IP44-56
Insulation Class: B/F/H
Ambient Temperature: 0℃~45℃
Frame Size: 63~560
Keywords: Y-H Series Marine Three-phrase Asynchronous Motor, Three-phrase Motor, Asynchronous Motor, Y-H Series Motor
Type of starting
Direction on full voltage starting for all sizes, reduced voltage starting allowable at no-load or light load.
Impregnation and Surface Treatment
The electric motor windings are impregnated and well treated to obtain adequate damp-proof anti-fungus and anti-salt-mist properties in accordance with the specifications for humid-tropic machines.
Insulation Temperature Rise
Insulation——B/F
Temp. Rise of winding——75K/100K
Permissible working temp. of bearing(thermometer method)